435 Hamilton Street  
Allentown, Pa. 18101  
Allentown  
Meeting Agenda  
Planning Commission  
Tuesday, October 13, 2026  
12:15 PM  
Council Chambers  
Call to Order  
1. Approval of Minutes from the Public Meeting of September 8, 2026  
Sidewalk Postponement  
2. Project: 932 Walnut Street  
Applicant: Barry isett & Associates  
Location: 932 W Walnut Street  
Description: Request to postpone requirements of §545-13 for the maintenance and  
replacement of existing curbs and sidewalks.  
File: S 26-02  
Land Developments  
3. Bridgeview Academy Additions  
Applicant: Allentown School District  
Location: 265 Lehigh Street  
Description: Construction of a 2-story addition and a gymnasium addition with a  
pedestrian bridge and associated site improvements.  
File: LMA-2026-000013 (Preliminary/Final)  
Waivers requested: from SALDO Streetscape Area Regulations:  
§350-13.F(1): Alternative Compliance, Timing: An alternative  
method... such as a fee-in-lieu... may be approved  
provided pedestrian continuity is provided within no  
more than one year from completion of construction  
§350-13.G(2): Street Tree Area: A minimum 4-foot-wide street  
tree area, between the face of curb and the sidewalk,  
is required.  
§350-13.H(1): Minimum Streetscape: Applies all regulations in  
§13.G.  
§350-13.H(3)(a): Pavement Design: Paving materials and a pattern  
is required for each street.  
§350-13.H(3)(d): Lighting: Both pedestrian and vehicular lighting  
must be specified and locations and quantities  
noted.  
4. Project: 2401 W Emaus Avenue - Data Center  
Applicant: Quantm Group, LLC  
Location: 2401 W Emaus Avenue  
Description: Amended Preliminary / Final land development application of a  
previously approved 224,000 SF warehouse building to be revised into  
a Data Center use, adding an electrical substation, sound attention walls  
and associated site improvements.  
File: LMA-2022-00010 (Preliminary / Final - Amended) - Resubmission  
Waivers Requested: from existing conditions pending confirmation of SALDO  
§350-26.D: No opening from building shall be less than 1 foot  
above the curb elevation.  
§350-28.C(8): The bottom of the pond is to be sloped towards  
the outlet structure.  
§350-28.E(3): Storm sewers shall be required to have a minimum  
diameter of 15 inches and shall be made of  
reinforced concrete unless otherwise noted by the  
City Engineer, Sewers shall be installed in sufficient  
slopes to provide a minimum velocity of 3 feet per  
second and a maximum of 3 feet per second.  
§350-32.A: An easement of at least 20 feet in width must be provided  
along side and rear lot lines, labeled "General Utility  
Easements".  
Public Comment on Non-Agenda Items  
Adjournment  
!! APPLICANTS ARE REQUIRED TO ATTEND !!  
ANY QUESTIONS OR COMMENTS?  
Call: 610-437-7611 OR email: planning@allentownpa.gov  
Any updates to the agenda may be found at: